Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Cir. & cir ; 74(5): 351-357, sept.-oct. 2006. ilus, tab
Article in Spanish | LILACS | ID: lil-573413

ABSTRACT

Objetivo: identificar factores asociados a complicaciones con el manejo quirúrgico de las fracturas complejas de la meseta tibial. Material y métodos: estudio de casos y controles. Muestra integrada con expedientes de 56 pacientes diagnosticados con fractura compleja de la meseta tibial (tipos IV, V y VI de Schatzker), tiempo de seguimiento promedio de 12.9 ± 3.2 meses (8 a 18), y con uno o más de los siguientes factores de riesgo: edad mayor de 50 años, comorbilidad, tiempo de isquemia mayor de 60 minutos y fractura tipo IV, V o VI. Se consideró caso al paciente que presentara una o más complicaciones. Resultados: la edad promedio fue de 50.1 ± 15.7 años (17 a 87); 35 pacientes (62.5 %) pertenecieron al sexo masculino. Los pacientes con o sin complicaciones mostraron homogeneidad respecto a edad, sexo, lado, tipo de fractura y tiempo de seguimiento; 41.1 % presentó antecedentes patológicos. En todos los procedimientos se utilizó torniquete neumático. El tiempo promedio de cirugía fue de 91 ± 27.2 minutos (40 a 175). Los tratamientos empleados fueron placa más tornillos (53.6 %), fijadores externos más tornillos (35.7 %), doble placa y clavo centromedular. 37.5 % desarrolló complicaciones: infección superficial, 16.1 %; deformidades angulares residuales, 10.7 % (varo, 7.1 %); lesión del nervio peroneo, 5.4 %, pseudoartrosis, 3.5 %; trombosis venosa profunda, 1.8 %. Presentó más de una complicación, 22.2 %. Conclusiones: los factores de riesgo asociados significativamente a complicaciones con el manejo de la fractura compleja de la meseta tibial, fueron la edad mayor de 60 años y el tiempo de isquemia transoperatoria mayor de 120 minutos. Los pacientes en estas condiciones presentaron tres veces más riesgo para desarrollar complicaciones.


BACKGROUND: We undertook this study to identify factors associated with surgical complications of complex fractures of the tibial plateau. METHODS: We designed a case-control study with 56 patients with a diagnosis of complex fracture in the tibial plateau (IV-VI Schatzker) and with 12.9 +/- 3.2 (8-18) months of follow-up. Risk factor exposure was defined as having one or more of the following characteristics: age >60 years; co-morbidity (diabetes mellitus, systemic arterial hypertension); time of [quot ]Kidde[quot ] (>60, >90, >120 min) and fracture type IV, V or VI. A case was considered with one or more complications. Results: Mean age was 50.1 +/- 15.7 (17-87) years old; 35 patients (62.5%) were males. Homogeneity between groups was shown for age, sex, side effects, type of fracture and time of follow-up; 41.1% of patients had pathological history. All surgeries used pneumatic compression (Kidde) for 91 +/- 27.2 (40-175) min. The implants used were plate plus cancellous screws (53.6%), external fixators plus cancellous screws (35.7%), double plate and intramedullary nail. Complications appeared in 37.5% of all patients. Complications reported were superficial infection (16.1%), residual angular deformities (10.7%, varum [7.1%]), peroneal nerve injury (5.4%), non-union (3.5%) and deep venous thrombosis (1.8%); 22.2% of all patients presented more than one complication. CONCLUSIONS: Statistically significant risk factors were age >60 years and pneumatic compression >120 min. Patients with one of these characteristics had a three-times risk of complications. No association was demonstrated between type of fracture, surgical treatment, time between injury and the surgery, with development of complications.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged, 80 and over , Postoperative Complications/epidemiology , Fracture Fixation, Internal/methods , Fractures, Open/surgery , Tibial Fractures/surgery , Age Factors , Bone Plates , Bone Screws , Case-Control Studies , Comorbidity , Postoperative Complications/etiology , External Fixators , Follow-Up Studies , Fracture Healing , Fracture Fixation, Intramedullary/statistics & numerical data , Intermittent Pneumatic Compression Devices , Internal Fixators , Intraoperative Complications , Ischemia , Surgical Wound Infection/epidemiology , Peroneal Nerve/injuries , Perna/blood supply , Risk Factors , Tibial Fractures , Thrombophlebitis/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL